Sorry, the search criteria can not be empty
Search
View All Categories
Seasonal Sale! As usual see

Mini Light Tower produces 330,000 lumens

04/19/2013 06:52:07

Powered by single generator producing 3,250 VA, Model WAL-ML-3XM-3G is equipped with three 1,000 W metal halide lamps and adjustable light tower boom that can be elevated up to 12 ft in height using included hand winch, effectively illuminating 3 acres of work or event area. Lamp brackets allow each lamp to be adjusted independently, while heavy-duty rubber tires on base enable mobility.... ...

Read More

Material Handling Lifts handle up to 6,000 lb loads

04/19/2013 06:51:58

Designed to move large items or multiple pallets from floor to floor, Big Friggin Lift (BFL) series will travel from 8-18 ft and have platforms ranging from 6 x 8 ft up to 8 x 12 ft. Products built with tubular steel legs for optimal rigidity and equipped with Platform Centering Device. Additionally, lifts feature machine grade cylinders with return lines, oil reservoirs of mild steel, and double wire braid pressure hoses with JIC fittings. ... ...

Read More

NEMA publishes insulated stranded wire standard

04/19/2013 06:51:44

NEMA HP7 covers specific requirements for PVC, PVC/polyamide, PE, and PE/polyamide insulated stranded wire designed for internal wiring of high reliability electrical and electronic equipment. Publication addresses 600 V (Type B, BN, J, and JN), 1,000 V (Type C and CN) and 3,000 V (Type D and DN) wire and permits continuous operating temperature ratings of -55 to +105¡ãC or +75¡ãC (type J and JN only) with either tin or silver coated conductors. ... ...

Read More

NEMA publishes guidelines for electric fire pump controllers

04/19/2013 06:51:32

NEMA has published NEMA ICS 14-2010 for Application Guide for Electric Fire Pump Controllers and NEMA ICS 15-2011 for Instructions for the Handling, Installation, Operation, and Maintenance for Electric Fire Pump Controllers Rated Not More than 600V. NEMA ICS 14 stresses those considerations specific to fire pump installations, while NEMA ICS 15 helps avoid personal injury and equipment damage during various processes. ... ...

Read More

Rugged RJ45/SCSI-5 Patch Panel withstands extreme conditions

04/19/2013 06:51:09

Facilitating management of cable connections between data networks and data processing equipment, Model 9510 features 32 RJ45 ports wired to four 68-pin SCSI-5 connectors kitted with 4 SCSI-5 cables, strain relief bar, and fastener hardware. This 2U high, 19 in. wide patch panel, which mounts in standard rack, supports networks requiring means of accessing individual circuits for monitoring, interconnectivity, or testing. ... ...

Read More

NEMA welcomes House vote on U.S.-Russia trade

04/19/2013 06:51:06

NEMA congratulated strong bipartisan vote by House of Representatives to approve legislation to grant permanent normal trade relations status to Russia and provide access for U.S. businesses to the benefits of the entry of world's ninth largest economy into rules-based international trading system. Russian Federation formally joined the World Trade Organization on August 22, 2012, after many years of negotiations with the U.S. and other major trading partners. ... ...

Read More

Wheel Loader uses iT4-compliant, 354 hp, 6-cylinder diesel engine

04/19/2013 06:50:55

With 47,210 lb breakout force and 35,310 lb full-turn tipping capacity, DL420 is built for material handling applications such as quarries, mines, road work, and site development. High-lift configuration extends nominal dump height of 10 ft 1 in. by 2 ft, and hydraulic locking front differential is offered as option to standard limited slip differential. This 5.5 yd3 wheel loader also lets operators set upper and lower limits for both lift arm and bucket stop positions from inside cab. ... ...

Read More

Colored Split Loom cleanly organizes and protects cables

04/19/2013 06:50:23

By holding, protecting, and concealing cables, harnesses, hoses, and wires, colored split loom creates color-coded bundles that help keep electronic equipment in order and helps prevent tangling, snagging, and equipment failure. Construction is of flexible polyethylene, and slit automatically closes after installation. Protecting against abrasion, punctures, vibrations, and corrosive fluids, product comes in 4 colors, 6 diameters from ¼¡§C1 in., and 3 lengths from 5¡§C100 ft. ... ...

Read More

NEMA publishes application guideline for terminal blocks

04/19/2013 06:50:20

NEMA has published ICS 4-2010 Application Guideline, which applies to 1-piece, modular, or 2-piece terminal blocks with screw-type, screwless-type, or insulation displacement clamping units intended for industrial use and fixed to a support or PCB to provide electrical and mechanical connection for round, solid, or stranded conductors. Publication provides practical information concerning ratings, construction, test, performance, and manufacture of industrial control equipment. ... ...

Read More

Micro Radio Transceiver delivers scalable output power

04/19/2013 06:50:10

Intended for small-cell and macro-cell active antennas, Micro Radio Transceiver provides output power from 0.8-6.4 W by parallel use of P-Chips. Each P-Chip Doherty MMIC power amplifier delivers more than 39 dBm peak output power. Based on micro radio, uB700 Active Antenna System supports 4G in 700 MHz digital dividend band for broadband mobile networks, while uB900 supports GSM, UMTS, and LTE in 900 MHz band. Each micro radio can be controlled digitally and independently by central hub. ... ...

Read More

<<    <    ...   513 514 515 516 517    ...   >    >>      GO