Because of its unique, modular design, the Beckman P/ACE MDQ capillary electrophoresis system is ideal for research, methods development and quality control applications. The system can be rapidly reconfigured from a flexible research platform to a tightly regulated routine use platform. Capillary electrophoresis is utilized in many different industries, including basic biological research, pharmaceutical and biotechnology development, forensic and environmental science. Its popularity can be attributed to its simplicity, reliability, speed and versatility, combined with low operating costs and minimal waste production. Because P/ACE MDQ is designed as a combination of integrated modules, it can easily be configured to run a wide variety of procedures, fast and efficiently. An array of up to 36 pairs of buffers accessed randomly provides flexibility in optimizing methods development. This buffer array allows automation of the methods development process through the implementation of separation strategies, in that you can easily have the system test an array of different buffer pH levels, ionic strengths or additives. Once the method is developed, the array may be replaced with large-volume buffer reservoirs for routine analysis. The system is compatible with 96-well plates, 2ml vials, 0.5ml vials and PCR vials. MODES OF OPERATION: - constant/gradient voltage - constant/gradient current - constant/gradient power - variable pressure SAMPLE INTRODUCTION: Pressure, Vacuum, Electrokinetic VOLTAGE RANGE: - 1-30kV (1-10kV for injections) - Programmable in 0.1kV increments - Reversible voltage programmed through user interface CURRENT RANGE: 3-300uAmps PRESSURE RANGE: -5 to +100 psig (Rinse/Separations) -5 to +25 psig (Sample Introduction) Specifications for the P/ACE MDQ UV Detector: Wavelength Range 190 to 600 nm Filter Selection 200, 214, 254 and 280 nm (standard); three open positions for additional wavelength selections; filter diameter 1/2 inch (127 mm); 0.20 in. thick UV Source Deuterium Lamp; 30 W; prealigned Wavelength Accuracy 2 nm Analog Output Output 1 is Data; Full scale output is 1.0 AU/V (software selectable multipliers of 1.0, 0.5, 0.2, 0.05, 0.02 and 0.01 providing lower AU/V values). Output 2 not used. Output 3: Current signal when Voltage is programmed; Voltage signal when either Current or Power is programmed Service contract can be purchased from Beckman directly. Training, software & computer are not included but are available from the manufacturer's representative at additional cost. ITEM HAS BEEN PRICED ASSUMING IT HAS SAMPLE COOLING. WE WILL CONFIRM THIS UPON RECEIPT OF ORDER AND TESTING The following link provides additional information from the instruction manual or original manufacturer's brochure. Images, specifications and description refer to the item as it was when new. Right-click to open the PDF in a new window or download it: http://www.labequip.com/stock/pictures/26146.pdf
Similar Products
Condition : USED
Model#: P/ACE System MDQ
Location:
United States
Condition : Seller Refurbished
Model#: P/ACE 2100
Location:
United States
Condition : NEW
Model#: CEQ 8000
Location:
United States
Condition : Seller Refurbished
Model#: FC 500
Location:
United States
Model#: Ambient Carousel
Location:
San Diego, California, USA
Condition : Seller Refurbished
Model#: LS6500
Location:
United States
Model#: Biomek FX single 96 arm
Location:
Woburn, Massachusetts, USA
Model#: MW 96 / 384
Location:
Oceanside, California, USA
Model#: Biomek 3000
Location:
Mt. Airy, Maryland, USA
Condition : Seller Refurbished
Model#: LS6000
Location:
United States
Condition : USED
Model#: DTX880
Location:
United States
Condition : USED
Model#: Multiplex RIE System
Location:
United States