Agilent/HP 4140B pA Meter and DC Voltage Source

 

Agilent/HP 4140B pA Meter and DC Voltage Source

Rent me for $400 a month

   The Agilent/HP 4140B Picoammeter / DC Voltage Source, consists of an extremely stable picoampere meter and two programmable DC Voltage sources, one of which operates as a ramp and staircase generator as well as a DC Source. These features make the 4140B ideal for making DC characteristic measurements such as leakage current, current-voltage characteristics and quasi-static C-V measurements required by the semiconductor industry for new product development and for improving production yields.

Features
  • 3 basic semiconductor measurements: I, I-V and quasi-static C-V
  • Two programmable voltage sources
  • High resolution: 0.001 x 10-12 A
  • HP-IB standard
  • Stable pA Measurements
    * maximum resolution of 10-15 mA
    * low noise test leads, and an electrostatic and light shielded test fixture
  • Synchronized I-V Measurements
    * precise, programmable timing capability, we can now make fast, accurate I-V and C-V measurements
  • Quasi-Static C-V Measurements
    * automatic quasi-static C-V measurements are easily accomplished by the ramp voltage capability
  • HP-IB Capability

Specifications

  • Measurement Functions: I, I-V and C-V
  • Voltage Sources: two separate sources (VA and VB)
    VA: ± 100V programmable source/function generator
    VB: ± 100V programmable dc voltage source

Current Measurements

  • Displays: current, 3½ digits with 2 character annunciator.  Voltage, 3½ digits
  • Measurement range: ±0.001 x 10-12 A to 1.000 x 10-2 A full scale in 11 ranges
  • Overrange capability: 99.9% on all ranges
  • Range selection: auto (lowest current range is selectable) and manual
  • Zero Offset: cancels leakage current of test leads or test fixtures
  • Offset range: 0 to ± 100 x 10-15 A
  • Trigger: INT, EXT and HOLD/MAN
  • Input terminal: triaxial

Capacitance-Voltage (C-V) Measurement

  • Measurement ranges: 0.0 pF - 100.0 pF and 200 pF - 1000 pF full scale in two ranges; 99.9% overrange
  • Ranging: auto
  • % C: capacitance change of device under test is displayed as a percent of the set value of the oxide capacitance (Cox = 100%)
  • %C range: 0.0% - 199.9%
  • Cox setting ranges (2 ranges): 0.1 pF - 199.9 pF and 200 pF - 1999 pF
  • Zero offset: cancels stray capacitance of test fixtures and test leads
  • Offset range: 0 to 100 pF
  • High speed I data output: available with HP-IB interface only.  Outputs current measurement data at 4 ms intervals (max rate)

DC Voltage Sources

  • Voltage ranges (VA and VB): 0 to ± 10.00V and 0 to ± 100.0V in 2 ranges, auto range only
  • Maximum current: 10 mA, both sources
  • Voltage sweep: auto and manual (pause), up/down step in manual (pause) mode.   Sweep abort standard

Operating Parameter Setting Ranges

  • Start voltage and stop voltage: 0 - ± 10.00V, 0.01V steps; 0 - ± 100.0V, 0.1V steps
  • Step voltage: 0 - ± 10.00V, 0.01V steps; 0 - ± 100.0V, 0.1V steps
  • Hold time: 0 - 199.9 seconds in 0.1s increments; 0 - 1999 seconds in 1.0s increments