SPECIFICATIONS: (23°C ± 5°C)DC Current: | Range | Resolution | Accuracy | Overload protection |
| 400A | 0.1A | ± (2.0% + 5dgts) | 800A |
| 600A | 1A | ± (2.0% + 5dgts) | 800A |
AC Current: (Frequency response: 40Hz to 450Hz)| Range | Resolution | Accuracy | Overload protection |
| 400A | 0.1A | ± (2.0% + 5dgts) | 800A |
| 600A | 1A | ± (2.0% + 5dgts) | 800A |
DC Voltage: (Input Impedance 1MΩ)
| Range | Resolution | Accuracy | Overload protection |
| 600V | 1V | ± (0.75% + 2dgts) | 660Vrms |
AC Voltage: (Input Impedance 1MΩ and Frequency Response 40Hz to 450Hz)
| Range | Resolution | Accuracy | Overload protection |
| 400V | 0.1V | ± (1.2% ± 5dgts) | 660Vrms |
Frequency: (Voltage measurement: OL Protection 660Vrms)
| Range | Resolution | Accuracy | Sensitivity |
| 4kHz | 1Hz | ± (0.5% + 5dgts) | 1V |
| 20kHz | 10Hz | ± (0.5% + 5dgts) | 5V |
Frequency: (Current measurement: OL Protection 800A)
| Range | Resolution | Accuracy | Sensitivity |
| 4kHz | 1Hz | ± (0.5% + 5dgts) | 5A |
Resistance: (Open circuit voltage 0.5 volts DC)
| Range | Resolution | Accuracy | Overload Protection |
| 4kΩ | 1Ω | ± (1% + 5dgts) | 660Vrms |
General specifications:
| Applicable standards | IEC 1010-2-032, EN 61010-1, Pollution Degree 2 |
| Jaw opening | 40mm maximum |
| Display | 3¾ digit LCD with maximum reading of 3999 |
| Sampling rate | 2.5 times per second (digital display) |
| Operating temperature | 0°C to 40°C |
| Dimensions | 228(L) x 76(W) x 39(H)mm, (9" x 3" x 1.5") |
| Weight | 465g (batteries included), 1 lb |
| Accessories included | Instruction Manual, 9V Battery, Test Leads, Carrying Case |