At Fluke, our ideas come straight from the job site. We work with users like you to create test tools that do the job you want for as long as you need it—and give you full value. We design and build Fluke 80 Series multimeters in the U.S.A. The 80 series is backed by our limited lifetime warranty. And we back them with our limited lifetime warranty so you can work smarter, faster and safer.
The Fluke 80 Series consists of the following models:
Fluke 83 V Industrial DMM
Fluke 87 V True RMS Industrial DMM
Specifications Voltage DC Maximum Voltage: 1000V Accuracy: Fluke 83 V: ±(0.1%+1) Fluke 87 V: ±(0.05%+1) Maximum Resolution: Fluke 83 V: 100 µV Fluke 87 V: 10 µV Voltage AC Maximum Voltage: 1000V Accuracy: Fluke 83 V: ±(0.5%+2) Fluke 87 V: ±(0.7%+2) True RMS AC Bandwidth Fluke 83 V: 5kHz Fluke 87 V: 20kHz* *with low pass filter; 3db @ 1kHz Maximum Resolution: 0.1 mV Current DC Maximum Amps: 10A (20 A for 30 seconds maximum) Amps Accuracy: Fluke 83 V: ±(0.4%+2) Fluke 87 V: ±(0.2%+2) Maximum Resolution: Fluke 83 V: 0.01 mA Fluke 87 V: 0.01 µA Current AC Maximum Amps: 10A (20 A for 30 seconds maximum) Amps Accuracy: Fluke 83 V: ±(1.2%+2) Fluke 87 V: ±(1.0%+2) True RMS Maximum Resolution: 0.1 µA Resistance Maximum Resistance: 50 MΩ Accuracy: Fluke 83 V: ±(0.4%+1) Fluke 87 V: ±(0.2%+1) Maximum Resolution: 0.1Ω Capacitance Maximum Capacitance 9,999 µF Accuracy ±(1%+2) Maximum Resolution 0.01 nF Frequency Maximum Frequency 200 kHz Accuracy ±(0.005%+1) Maximum Resolution 0.01 Hz Duty Cycle Maximum Duty Cycle 99.9% Accuracy ±(0.2% per khz +0.1%) Maximum Resolution 0.1% Temperature Measurement Fluke 87 V, 87 V/E: -200.0°C - 1090°C -328.0°F - 1994.0°F excluding probe 80 BK Temperature Probe -40.0°C - 260°C -40.0°F - 500°F, 2.2°C or 2% whichever is greater Conductance Maximum Conductance 60.00 nS Accuracy ±(1.0%+10) Maximum Resolution 0.01 nS Diode Range: 3 V Resolution: 1 mV Accuracy: ± (2 % + 1) Duty Cycle Range Accuracy: Within ± (0.2% per kHz + 0.1 %) Environmental Specifications Operating Temperature -20°C to +55°C Storage Temperature -40°C to +60°C Humidity (Without Condensation) 0% - 90% (0°C - 35°C) 0% - 70% (35°C - 55°C) Operating Altitude 2000 m Safety Specifications Overvoltage category EN 61010-1 to 1000 V CAT III, 600V CAT IV Agency Approvals UL, CSA, TÜV, VDE listed Mechanical & General Specifications Size 201 x 98 x 52 mm (with holster) Weight 355 g Weigh With Holster and Flex-Stand 624 g Display Digital: 6000 counts updates 4/sec. (Model 87 also has 19,999 counts in high-resolution mode.) Analog: 32 segments, updates 40/sec. Frequency: 19,999 counts, updates 3/sec at > 10 Hz. Warranty Lifetime Battery Life Alkaline: ~400 hours typical, without backlight Shock 1 Meter drop per IEC 61010-1:2001 Vibration Per MIL-PRF-28800 for a Class 2 instrument