  • DC/AC 0.01A resolution

  • 23mm Jaw Diameter

  • Temperature and Capacitance

  • Autorange V, Ω, Hz, °C, °F, –| |–

  • AC/DC 0.01A to 200A

  • 0 to 9999 RPM with optional Adapter

  • 3¾ digits, 4000 counts of resolution

  • Max/Min/Hold/Relative

  • Price: $325.00 US dollars



SPECIFICATIONS: (23°C ± 5°C)
DC Current

RangeResolutionAccuracyOverload Protection
40A10mA± 1.5% ± 2dgts400 amps DC
0-150A100mA± 1.5% ± 2dgts400 amps DC
150-200A100mA± 2.2% ± 2dgts400 amps DC


AC Current

AccuracyOverload Protection
RangeResolution50/60 Hz40Hz - 1kHz
40A10mA± 1.5% ± 3dgts± 2.0% ± 4dgts400 amps AC
0-150A100mA± 1.5% ± 3dgts± 2.0% ± 4dgts400 amps AC
150-200A100mA± 2.2% ± 3dgts± 2.5% ± 4dgts400 amps AC


DC Voltage: (Overload protection 600V)

RangeResolutionAccuracyInput Impedance
40mV0.1 mV± 1.5% ± 3dgts10MΩ
4V1 mV± 1.5% ± 3dgts5MΩ
40V10 mV± 1.5% ± 3dgts5MΩ
400V100 mV± 1.5% ± 3dgts5MΩ
600V1V± 1.5% ± 3dgts5MΩ


Continuity: (Open voltage 0.4V, overload protection AC 600V)

RangeResolutionAccuracyOverload Protection
40-400Ω0.1Ω± 1.0% ± 2dgts< 40.0Ω (approx)


AC Voltage: (Input impedance 5 MΩ)

AccuracyOverload Protection
RangeResolution50/60 Hz40Hz - 1kHz
0.01-4V1 mV± 1.5% ± 5dgts± 2.0% ± 5dgts800 volts AC
40V10 mV± 1.5% ± 5dgts± 2.0% ± 5dgts800 volts AC
400V100 mV± 1.5% ± 5dgts± 2.0% ± 5dgts800 volts AC
600V1V± 1.5% ± 5dgts± 2.0% ± 5dgts800 volts AC


Resistance: (Open voltage 0.4V)

RangeResolutionAccuracyOverload Protection
400Ω0.1Ω± 1.5% ± 2dgts600 volts AC
4kΩ1Ω± 1.5% ± 2dgts600 volts AC
40kΩ10Ω± 1.5% ± 2dgts600 volts AC
400kΩ100Ω± 1.5% ± 2dgts600 volts AC
4MΩ1kΩ± 1.5% ± 2dgts600 volts AC
40MΩ10kΩ± 1.5% ± 2dgts600 volts AC


Frequency: (Auto, sensitivity selected by pressing RANGE button)

RangeResolutionAccuracySensitivityOL Protection
100Hz-100kHz0.01 - 100Hz± 0.5% ± 2dgts0.01/0.1/1V600 volts AC


RPM: (Requires optional RPM Adapter)

RangeResolutionAccuracyOverload Protection
0 Hz to 9999 Hz1 RPM± 0.5% ± 2dgts600 volts AC


Temperature: (Type K thermocouple with Adapter, °C or °F)

RangeResolutionAccuracyOverload Protection
-40°C to 0°C0.1 °C± 2% ± 2°C600 volts AC
0°C to 400°C0.1 °C± 0.5% ± 2°C600 volts AC
400°C to 1000°C1 °C± 0.5% ± 2°C600 volts AC
-40°F to 0°F0.1 °F± 2% ± 4°F600 volts AC
0°F to 400°F0.1 °F± 0.5% ± 4°F600 volts AC
400°F to 1000°F1 °F± 0.5% ± 4°C600 volts AC


Capacitance:

RangeResolutionAccuracyOverload Protection
4nF1pF± 5% ± 0.2nF600 volts AC
40nF10pF± 5% ± 0.2nF600 volts AC
400nF0.1nF± 3% ± 0.2nF600 volts AC
4μF1nF± 3% ± 0.02μF600 volts AC
40μF10nF± 3% ± 0.02μF600 volts AC


General specifications:

Applicable standardsEN 61010-2-032, CAT II 600V, CAT III 300V, Pollution Degree 2
Conductor size23mm maximum
Display3¾ digit LCD with 40 segment bar graph
Operating temperature-10°C to 50°C
Dimensions183(L) x 64(W) x 36(H)mm, (7.2" x 2.5" x 1.4")
Weight190g (batteries included), 6.7oz
Accessories includedUser's Manual, Batteries, Adapter (for capacitance and thermocouple), Carrying Bag