DA101010: 10 MHz Distribution Amplifier by Precision Test Systems LTD
- Item Condition:
- Brand:
- Model#:
- Location:
- Price:
Product Description
Key Features
• 10 MHz Main Input
• AGC Level Controlled
• 10 sinewave outputs plus a slave
• 2 squarewave outputs
• High channel isolation
• Low Phase Noise
• Optional second 10 MHz “Back-up” input
• Optional internal 10 MHz back-up oscillator
• Above two options automatically switched in
• Optional Alarm Relay, enabled on alarm condition
• Optional Redundancy (two units with automatic switchover)
• Available in other frequencies from 1 to 100 MHz.
General Description
The DA101010 can be used to synchronize up to thirteen instruments (ten sinewave, two squarewave and one slave
output) to a frequency reference input. The reference input frequency is 10 MHz and the output frequency is exactly
the same as the input. The DA101010 incorporates AGC (automatic gain control) so that a 10 MHz input can be
varied from -10 dBm to +20 dBm without the outputs changing by more than 0.4 dB. Inputs as low as -30 dBm still
produce a useable output. The pure sinewave output (harmonics are typically 70 dB down) enables the DA101010 to
work in the most demanding applications.
Outputs
There are ten 10 MHz, sinewave outputs. Each 10 MHz output is isolated from the input and each other. Therefore
the reference oscillator connected to the DA101010 input is protected against load variations, short circuits etc. that
may be applied to the outputs. Two additional squarewave outputs can be switched in frequency from 10 MHz, 5
MHz, 2 MHz, 1 MHz, 100 kHz and 1 pps. These outputs are ideal for instruments that do not use a 10 MHz
timebase. A rear slave output can be connected to a second DA101010 (or more) to give additional outputs. See
“Applications” below. There is also a TTL alarm output. This TTL signal will show when a valid input signal is
present.
Allan Deviation
The DA101010 has very low Allan deviation, lower than most oscillators or frequency sources. This means the
DA101010 will not increase the Allan deviation of the source connected to it.